recreen logo 03

120kWh Outdoor Lithium Battery Storage Cabinet

Integrated outdoor lithium battery cabinet with intelligent BMS, HVAC cooling, and fire suppression system for flexible commercial ESS integration.

Download

RECREEN 120KWH Battery Energy Storage Systems

Compatible With Multiple PCS & Inverter Brands

  • The battery cabinet is designed with an open integration architecture, allowing flexible compatibility with various local and international PCS or inverter platforms.

    Compatible applications include:

    • Commercial hybrid inverter systems
    • AC-coupled ESS projects
    • DC-coupled solar storage systems
    • Microgrid applications
    • Off-grid energy systems
    • Retrofit energy storage projects

    This flexible integration capability allows customers to match the battery cabinet with locally preferred inverter brands and energy management systems.

Integrated Outdoor ESS Cabinet Design

  • The outdoor cabinet integrates:

    • High-voltage lithium battery system
    • Intelligent BMS
    • Industrial air conditioning system
    • Fire suppression system
    • Safety protection architecture
    • Communication interface
    • Outdoor-rated enclosure

    within a compact and deployment-ready platform.

    The integrated design simplifies transportation, installation, commissioning, and long-term operation.

Plug-and-Play DC Battery Platform

  • The cabinet is engineered for simplified project deployment and faster system integration.

    Key deployment advantages include:

    • Factory pre-installed architecture
    • Simplified DC-side connection
    • Faster commissioning
    • Reduced on-site wiring
    • Easier system debugging
    • Flexible inverter matching

    The plug-and-play design helps EPCs reduce engineering complexity and accelerate project delivery timelines.

Scalable For Future Energy Demand

Safety is built into the entire cabinet architecture.

The system includes:

  • Automatic fire suppression system
  • Smoke detection
  • Temperature monitoring
  • Gas detection
  • Emergency protection logic
  • Intelligent BMS protection

The multi-layer safety design improves operational reliability and supports stable long-term commercial operation.

Easy Installation & Simplified Commissioning

  • The cabinet is designed to reduce project deployment complexity and improve installation efficiency.

    Compared with traditional containerized ESS systems, the outdoor cabinet offers:

    • Smaller footprint
    • Easier transportation
    • Simplified installation
    • Faster commissioning
    • Flexible deployment
    • Reduced engineering workload

    The platform is especially suitable for distributed commercial energy storage projects.

Flexible Energy Storage Integration

The DC battery cabinet can be integrated into multiple commercial energy architectures including:

  • Solar + storage systems
  • Commercial ESS projects
  • EV charging infrastructure
  • Backup power systems
  • Microgrid applications
  • Industrial energy optimization
  • Peak shaving projects

The flexible DC-side architecture allows customers to customize ESS configurations according to local project requirements.

Overview

DC 120kWh Battery Energy Storage Systems

Maximum Battery Capacity
Configuration Capacity
Safety/EMC
Compatible High Voltage Hybrid Inverters
Diseño de vida
Cooling Method
120KWH
72.3kWh ~ 217 kWh
UN38.3, IEC62619, IEC63056, IEC62477-1, IEC61000-6-2/4
Solis/ Deye/ Sungrow/ Victrom and Other Brands
10 años
Air Cooled

Description

Flexible DC Lithium Battery Storage Platform For Commercial Energy Applications

The Recreen 120KWh Outdoor Lithium Battery Cabinet is designed as a flexible DC-side energy storage platform for commercial and industrial applications.

Integrated with high-voltage lithium battery clusters, intelligent BMS, air conditioning thermal management, and fire protection systems, the cabinet enables seamless compatibility with a wide range of local PCS and inverter brands.

The modular DC-coupled architecture provides EPCs, system integrators, and energy developers with greater flexibility for customized commercial ESS projects.

Product ModelF100-MF200-M
Maximum Battery Capacity120.7kWh217kWh
Configuration Capacity72.3kWh~217kWh72.3kWh~217kWh
Maximum Photovoltaic Power60kW100kW
Maximum Battery Power33kW55kW
Maximum Generator Power30kW50kW
Maximum Output Power30kW50kW
Tensión nominal3/N/PE,220V/380V,3/N/PE,230V/400V3/N/PE,220V/380V,3/N/PE,230V/400V
Output Current45.6A/43.3A76A/72.2A
Maximum Bypass Current91.2A/86.6A152A/144.4A
Rated Frequency50/60 Hz50/60 Hz
Off Grid Switching Time<10ms<10ms
MPPT Voltage150~850V
150~850V
MPPT Quantity3*64*8
Maximum Photovoltaic Current3*40A4*40A
Maximum Charging Efficiency98.5%98.5%
CellLFP~3.2V~314aH~1004.8WhLFP~3.2V~314aH~1004.8Wh
Battery Voltage Range330V~426V 594~766.8Vdc
Maximum Current of Battery70A*270A*2
Battery Cell System Lifespan≥10000≥10000
Battery Cycle Efficiency 91%91%
Generator Current45.6A/43.3A76A/72.2A
Generator Voltage 3/N/PE,220V/380V,3/N/PE,230V/400V 3/N/PE,220V/380V,3/N/PE,230V/400V
Protection FunctionIsland protection,overcurrent protection,short circuit protection,reverse connection protection,surge protection,ectIsland protection,overcurrent protection,short circuit protection,reverse connection protection,surge protection,ect
BMS TopologyBidirectional active equilibriumBidirectional active equilibrium
Interfaz de comunicación RS484/Can Ethernet/MQTT RS484/Can Ethernet/MQTT
Firefighting Program Fire detector+gas/smoke/temperature detection+perfluorohexaneFire detector+gas/smoke/temperature detection+perfluorohexane
Isolation MethodNon-IsolatedNon-Isolated
Outlet Lower outgoing lineLower outgoing line
Altitude ≤4000M(>3000m Derating)
Temperatura de funcionamiento-20~50℃-20~50℃
Degree of ProtectionIP55IP55
Max Configuration Weight1.2T1.9T
Dimensions W*D*H1000*1274*2000mm1435*1274*1780mm
Product CertificationGBT36276. GBT34131.CE.IEC62619.IEC62477-2.UN38.3GBT36276. GBT34131.CE.IEC62619.IEC62477-2.UN38.3
Power Grid StandardsGB/T 29319,G98/G99,VDE-AR-N 4105/ VDE V 0124,EN50549-1,VDE 0126/UTE C 15/ VFR:2019,RD 1699/ RD 244/UNE 206006/UNE 206007-1,CEI 0-21,C10/11,NRS097-2-1,TOR,EIFS 2018.2,IEC 62116,IEC 61727,IEC 60068,IEC 61683,EN 50530,MEA,PEAGB/T 29319,G98/G99,VDE-AR-N 4105/ VDE V 0124,EN50549-1,VDE 0126/UTE C 15/ VFR:2019,RD 1699/ RD 244/UNE 206006/UNE 206007-1,CEI 0-21,C10/11,NRS097-2-1,TOR,EIFS 2018.2,IEC 62116,IEC 61727,IEC 60068,IEC 61683,EN 50530,MEA,PEA

 