{"id":4124,"date":"2026-05-20T12:31:38","date_gmt":"2026-05-20T20:31:38","guid":{"rendered":"https:\/\/recreen.com\/?post_type=product&#038;p=4124"},"modified":"2026-05-20T12:43:13","modified_gmt":"2026-05-20T20:43:13","slug":"522kwh-battery-storage-cabinet","status":"publish","type":"product","link":"https:\/\/recreen.com\/es\/products\/522kwh-battery-storage-cabinet\/","title":{"rendered":"522KWh Battery Storage Cabinet Commercial Energy Storage Solution"},"content":{"rendered":"<h3 data-section-id=\"14ncka1\" data-start=\"282\" data-end=\"354\">High-Density Energy Storage for Commercial &amp; Industrial Applications<\/h3>\n<p data-start=\"356\" data-end=\"489\">A liquid-cooled battery cabinet engineered for scalable energy storage, simplified deployment, and long-term operational reliability.<\/p>\n<p data-start=\"491\" data-end=\"605\">Designed for AC-coupled energy storage systems and flexible integration across commercial and industrial projects.<\/p>\n\n<table id=\"tablepress-26\" class=\"tablepress tablepress-id-26\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">Product Model<\/th><th class=\"column-2\">L522<\/th><th class=\"column-3\">L261<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">Rated Electric <\/td><td class=\"column-2\">522.496kWh<\/td><td class=\"column-3\">261.248kWh<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">Charge\/Discharge Ratio <\/td><td class=\"column-2\">0.25CP\/0.5CP<\/td><td class=\"column-3\">0.5CP<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">Rated AC Power<\/td><td class=\"column-2\">125kW\/250kW<br \/>\n<\/td><td class=\"column-3\">125kW<\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">Cell<\/td><td class=\"column-2\">LFP-3.2-314Ah-1004.8Wh<br \/>\n<\/td><td class=\"column-3\">LFP-3.2-314Ah-1004.8Wh<\/td>\n<\/tr>\n<tr class=\"row-6\">\n\t<td class=\"column-1\">Pack <\/td><td class=\"column-2\">LFP-166.4V-52.2kWh<\/td><td class=\"column-3\">LFP-166.4V-52.2kWh<\/td>\n<\/tr>\n<tr class=\"row-7\">\n\t<td class=\"column-1\">Rated DC Voltage<\/td><td class=\"column-2\">832Vdc<\/td><td class=\"column-3\">832Vdc<\/td>\n<\/tr>\n<tr class=\"row-8\">\n\t<td class=\"column-1\">Operating Voltage Range <\/td><td class=\"column-2\">715~923Vdc<\/td><td class=\"column-3\">715~923Vdc<\/td>\n<\/tr>\n<tr class=\"row-9\">\n\t<td class=\"column-1\">Maximum DC Current<\/td><td class=\"column-2\">175A\/350A<br \/>\n<\/td><td class=\"column-3\">200A<\/td>\n<\/tr>\n<tr class=\"row-10\">\n\t<td class=\"column-1\">System Lifespan<\/td><td class=\"column-2\">8000 time @25\u2103\uff0c0.5CP\uff0c95%DOD, \u226570%EOL<\/td><td class=\"column-3\">8000 time @25\u2103\uff0c0.5CP\uff0c95%DOD, \u226570%EOL<\/td>\n<\/tr>\n<tr class=\"row-11\">\n\t<td class=\"column-1\">Cyclic Efficiency<\/td><td class=\"column-2\">AC Side\u226588%<\/td><td class=\"column-3\">AC Side\u226588%<\/td>\n<\/tr>\n<tr class=\"row-12\">\n\t<td class=\"column-1\">BMS Topology<\/td><td class=\"column-2\">Bidirectional active equilibrium<\/td><td class=\"column-3\">Bidirectional active equilibrium<\/td>\n<\/tr>\n<tr class=\"row-13\">\n\t<td class=\"column-1\">Interfaz de comunicaci\u00f3n<\/td><td class=\"column-2\">RS485\/CAN\/Ethernet\/MQTT<br \/>\n<\/td><td class=\"column-3\">RS485\/CAN\/Ethernet\/MQTT<\/td>\n<\/tr>\n<tr class=\"row-14\">\n\t<td class=\"column-1\">HVAC<\/td><td class=\"column-2\">Intelligent liquid cooling<\/td><td class=\"column-3\">Intelligent liquid cooling<\/td>\n<\/tr>\n<tr class=\"row-15\">\n\t<td class=\"column-1\">Firetighting Program<\/td><td class=\"column-2\">Fire detector+gas\/smoke\/temperature detection+perfluorohexane<br \/>\n<\/td><td class=\"column-3\">Fire detector+gas\/smoke\/temperature detection+perfluorohexane<\/td>\n<\/tr>\n<tr class=\"row-16\">\n\t<td class=\"column-1\">Grid Voltage<\/td><td class=\"column-2\">400vAC (Three-phase four-wire)<br \/>\n<\/td><td class=\"column-3\">400Vac\uff08Three-phase four-wire\uff09<\/td>\n<\/tr>\n<tr class=\"row-17\">\n\t<td class=\"column-1\">Rated AC Current <\/td><td class=\"column-2\">180A\/360A<br \/>\n<\/td><td class=\"column-3\">180A<\/td>\n<\/tr>\n<tr class=\"row-18\">\n\t<td class=\"column-1\">Rated Grid Frequency<\/td><td class=\"column-2\">50\/60 Hz<\/td><td class=\"column-3\">50\/60 Hz<\/td>\n<\/tr>\n<tr class=\"row-19\">\n\t<td class=\"column-1\">Isolation Method<\/td><td class=\"column-2\">Non-isolated<br \/>\n<\/td><td class=\"column-3\">Non-Isolated<\/td>\n<\/tr>\n<tr class=\"row-20\">\n\t<td class=\"column-1\">Outlet <\/td><td class=\"column-2\">Bottom outgoing line<\/td><td class=\"column-3\">Bottom outgoing line<\/td>\n<\/tr>\n<tr class=\"row-21\">\n\t<td class=\"column-1\">Altitude<\/td><td class=\"column-2\">\u22643500m ( >2000m Derating )<\/td><td class=\"column-3\">\u22643500m\uff08\uff1e2000m Derating\uff09<\/td>\n<\/tr>\n<tr class=\"row-22\">\n\t<td class=\"column-1\">Temperatura de funcionamiento<\/td><td class=\"column-2\">-20\u2103 ~ 50\u2103<br \/>\n<\/td><td class=\"column-3\">-20\u2103 ~ 50\u2103<\/td>\n<\/tr>\n<tr class=\"row-23\">\n\t<td class=\"column-1\">Degree of Protection<\/td><td class=\"column-2\">IP55<\/td><td class=\"column-3\">IP55<\/td>\n<\/tr>\n<tr class=\"row-24\">\n\t<td class=\"column-1\">Max Configuration Weight<\/td><td class=\"column-2\">5T <\/td><td class=\"column-3\">2.2T<\/td>\n<\/tr>\n<tr class=\"row-25\">\n\t<td class=\"column-1\">Dimensions W*D*H<\/td><td class=\"column-2\">1710*1200*2000mm<\/td><td class=\"column-3\">865x1200x2200mm<\/td>\n<\/tr>\n<tr class=\"row-26\">\n\t<td class=\"column-1\">Product Certification<\/td><td class=\"column-2\">GBT36276,GBT34131,CE,IEC62619,IEC62620,IEC62477-1,UN38.3<\/td><td class=\"column-3\">GBT36276,GBT34131,CE,IEC62619,IEC62620,IEC62477-1,UN38.3<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-26 from cache -->","protected":false},"excerpt":{"rendered":"<p><strong>522kWh Battery Cabinet | Liquid-Cooled Commercial Energy Storage System<\/strong><\/p>\n<p>522kWh liquid-cooled battery cabinet for commercial and industrial energy storage applications. Designed for AC-coupled ESS deployment with flexible PCS compatibility, simplified commissioning, and scalable battery architecture.<\/p>","protected":false},"featured_media":4056,"template":"","meta":{"_acf_changed":false,"_seopress_robots_primary_cat":"none","_seopress_titles_title":"522kWh Battery Storage Cabinet Factories","_seopress_titles_desc":"battery storage factories,522kwh battery storage,commercial energy storage solutions,522kwh battery,522kwh battery storage systems,522kwh lithium battery,bess,522kwh bess","_seopress_robots_index":""},"product_brand":[],"product_cat":[94,37],"product_tag":[],"class_list":{"0":"post-4124","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-commercial-energy-storage-systems","7":"product_cat-energy-storage-systems","9":"first","10":"instock","11":"shipping-taxable","12":"product-type-simple"},"acf":[],"_links":{"self":[{"href":"https:\/\/recreen.com\/es\/wp-json\/wp\/v2\/product\/4124"}],"collection":[{"href":"https:\/\/recreen.com\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/recreen.com\/es\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/recreen.com\/es\/wp-json\/wp\/v2\/media\/4056"}],"wp:attachment":[{"href":"https:\/\/recreen.com\/es\/wp-json\/wp\/v2\/media?parent=4124"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/recreen.com\/es\/wp-json\/wp\/v2\/product_brand?post=4124"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/recreen.com\/es\/wp-json\/wp\/v2\/product_cat?post=4124"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/recreen.com\/es\/wp-json\/wp\/v2\/product_tag?post=4124"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}